Skip to main content
Humidity generator Huminator II

Humidity generator

Huminator II.

Calibration equipment

Huminator II

Simple and precise humidity calibration of measuring instruments, probes and data loggers of all manufacturers

The Huminator II is a compact and portable calibration system for manufacturer-independent humidity calibration of your measuring devices. It is therefore flexible and can be used for various industrial and laboratory tasks and at the same time for different mobile or stationary service purposes. The large measuring chamber with a diameter of Ø 160 mm allows parallel calibration of up to 5 probes or loggers. At the same time, the time-based programming function allows extensive automation of calibrations. Up to 10 humidity/temperature values per measuring programme can be generated automatically one after the other and the stability time can be freely selected. The integrated reference sensor reduces your downtimes and enables fast recalibration.

Your advantages at a glance:

  • Wide temperature and humidity range from 5 °C to 50 °C and from 5 %RH to 95 %RH
  • Quick and intuitive operation through touch display 
  • Stable readings due to chamber insulation and high sealing adapter plate
  • Exceptional performance at high lead times and continuous operation
  • Transportable condition due to fully automatic pumping down
  • Compact size and low weight

With the Huminator II, temperature and humidity values are set simultaneously. Peltier elements ensure stable, integrated temperature control in the range from 5 to 50 °C. The relative humidity can be controlled in the range from 5 to 95 %rh. The humidity values can be precisely controlled by the internally installed humidifier and the dry cartridge. A reference sensor integrated in the measuring chamber provides constant control. 

The Huminator II thus functions according to the principle of the two-quantity generator. The desired humidity and temperature points can be set automatically on the unit by programming a sequence. Calibrations can be conveniently carried out in two different ways. It is possible to make the settings directly on the Huminator II's resistive touch display or to control them on a computer via the available USB or Ethernet interfaces.

Humidity calibration Huminator – Process

Your contact

Please call us at:

+49(0)7661 90901-8000

(*) Yes, I have read the data protection declaration and  agree that the data I provide will be collected and stored electronically. My data will only be used strictly for the purpose of processing and responding to my request. I agree that Testo Industrial Services GmbH may pass on my data to certified service partners for processing and answering my request.